RC-7Bi Series
Features and Benefits
|
|
 |
Primary
Applications: Indoor electromechanical controller for residential use.
Ideal for areas subject to either electrical storm activity or power surges, as
well as applications where programming ease is essential.
Features and
Benefits:
- Independent station timing knobs make this controller the
easiest to program, read, and understand.
- Electromechanical design for best reliability and
electrical surge resistance.
- 24-hour clock (automatic starts on any hour except
midnight) allows automatic irrigation cycles day or night and provides for
multiple, repeat cycles.
- Easy, at-a-glance programming provides a visual display of
the watering schedule.
- Master valve/remote pump start circuit for optimal
irrigation control.
- External, plug-in transformer (U.S./Canada) provides
convenient installation.
- Front panel-mounted fuse for easy access and quick
diagnostics.
- Quick-connect plug on front panel for ease of installation.
- Indoor-mount cabinet for clean-looking, professional
installation.
- Latch accepts padlock for greater security.
- Compact size saves space. Master on/off switch allows
shutdown for rain, winter season, and maintenance.
- UL Listed; CSA, CE
approved.
Models:
- RC-4Bi: 4 stations
- RC-7Bi: 7 stations
- RC-1260Bi: 12 stations
- RC-4Bi-50Hz: 4 stations, 230VAC, 50Hz
- RC-7Bi-50Hz: 7 stations, 230VAC, 50Hz
- RC-1260Bi-50Hz: 12 stations, 230VAC,
50Hz
Specifications:
- RC-4Bi: Station timing: 3-60 minutes (in 1-minute
increments)
- RC-7Bi: Station timing: 3-60 minutes (in 1-minute
increments)
- RC-1260Bi: Station timing: 6-60 minutes (in 2-minute
increments)
- Automatic starts: 1 to 23 per day
- Programming schedule: 14-day calendar dial for every-day,
every-other-day, and other pattern starts for a 2-week period
- Input required: 117VAC, 60Hz external plug-in transformer
(U.S./Canada) or 230VAC, 50Hz input transformer
- Output: 24VAC, 60Hz or 50Hz, 1.25A
- 1.5A fuse in front panel-mounted holder
- Station capacity: One 24VAC, 7VA solenoid valve per station
when master valve/pump start circuit is used; up to two valves per station when
master valve/pump start circuit is not in use
- Station timing: 0 to 12 hours for all stations (0 to 16 hours with water budgeting); 0 to 120 minutes selectable in 1-minute increments; above 120 minutes selectable in 10-minute increments
- Automatic starts: 6 starts per day for each program, available on the quarter hour (total of 24 start times)
- Independent programming schedule options:
- 1. ODD day watering (per program)
- 2. EVEN day watering (per program)
- 3. CYCLICAL (1 to 31 days, variable per program)
- 4. CUSTOM (weekly schedule variable per program)
- Input required: 117 VAC ± 10%, 50/60 Hz (International models 230 VAC ± 10%, 50/60 Hz
- Output: 26.5 VAC, 1.5A (1.25A on ESP-LXi+)
- Diagnostic circuit breaker skips and indicates stations with overloaded circuits and continues to run operable stations
- Overload, backup fuse: 1.5A SLO-BLO (1.25A SLO-BLO on ESP-LXi+)
- Battery backup: 9V Ni-MH rechargeable battery (included) for programming under battery power and maintaining program current time and date during power outages
- Station Capacity: Up to two 24 VAC, 7VA solenoid valves per station plus a master valve or pump start relay
- Terminal strips for up to #12UF wire
- Electrical surge protection: Primary input side has built-in MOV (metal oxide varistor) to protect microcircuitry; output side has one built-in MOV for each valve station
|
|
 |
|
|
|
|
Helpful Tools
|
|
|
|
|